Datasets

手首で歩行を測った、公開データの索引。

手首装着の慣性センサーで歩行が記録されている公開データセットを、実際に使えるかどうかを決める軸——装着部位、サンプリング周波数、正解ラベルの種類、入手手続き——で引けるようにまとめています。

絞り込み45 件中 45 件を表示

歩行ベンチマーク13

歩行・歩数の解析のために作られ、歩行イベントの基準を持つもの。手首からの歩数推定を評価するなら、まずここです。

データセット被験者装着部位サンプリング正解ラベル入手確認日
Clemson Pedometer Dataset
Pedometer Evaluation Dataset (Clemson University) · 2017
Gyroscope and magnetometer data exist only in the separate RawData.zip; the synchronised release (9 columns, wrist/hip/ankle) is accelerometer-only, and both streams run at ~15 Hz. Annotations distinguish true steps from 'shifts' (pivots, shuffles, first/last stride), so step-count evaluations that ignore shifts will mis-score; note cecas.clemson.edu serves over plain HTTP only (broken HTTPS chain), with the Google Sites page carrying the CC BY 4.0 dataset license.
30
wristhipankle
15
ジャイロあり
歩行イベント
~60,800 individual step events manually annotated frame-by-frame from synchronised video of the feet, labelled left/right and separated from non-step 'shifts'.
自由
CC BY 4.0
2026-07-27
MAREA
MAREA gait database (Movement Analysis in Real-world Environments using Accelerometers) · 2017
One of the very few datasets pairing a wrist accelerometer with hardware-measured (FSR) per-step gait events across treadmill, indoor and outdoor conditions; the wrist sensor is left-wrist only and there is no gyroscope. Download links are emailed after signing a release agreement, no subject appears in every condition (11 indoor vs 9 outdoor), and the right-ankle sensor is mounted in an arbitrary orientation.
20 (11 indoor, 9 outdoor)
waistwristankle
128
加速度のみ
歩行イベント
Heel-strike and toe-off events from piezo-electric force-sensitive resistors at the ends of the shoe sole, recorded synchronously with the accelerometers.
登録要
custom release agreement (not open)
2026-07-27
Mobilise-D TVS
Mobilise-D Technical Validation Study (TVS) dataset · 2024 (v1.0.2 released July 2025)
Among the strongest reference annotations in this index (real-world stride-level ground truth in impaired cohorts), and the wrist unit is a full INDIP magneto-inertial module (accelerometer + gyroscope, 100 Hz) present for 105 of 108 participants — but only in v1.0.2, so earlier records such as zenodo.org/records/13987963 contain no wrist data at all. The record's licence is internally contradictory (description text CC BY-NC-ND 4.0 vs. metadata CC BY 4.0), and all turning parameters were removed from the reference as unvalidated, so there is no turning ground truth.
108 (across 6 cohorts)
wristlower backfoot
100
ジャイロあり
歩行イベント
Marker-based stereophotogrammetric motion capture for the in-lab tests plus the INDIP multi-sensor reference system (two plantar pressure insoles, three IMUs, two distance sensors) for lab and free-living, giving stride-level gait events and spatio-temporal parameters at micro-walking-bout and continuous-walking-period level.
自由
CC BY-NC-ND 4.0 (Zenodo metadata field says CC BY 4.0)
2026-07-27
MoveSmart
MoveSmart: A multi-modal dataset for ground reaction force estimation using Apple Watch and force plate data · 2025
The only public pairing of a consumer smartwatch with force-plate ground truth, so contact events come from measured force rather than from another IMU. Small and laboratory-bound. Primary sources disagree on the licence — the canonical Zenodo deposit says CC0, so confirm before relying on it commercially.
10
wristwaist
100
ジャイロあり
歩行イベント
AMTI OR6-7 force plate at 1000 Hz, time-aligned to the watch IMU; vertical ground reaction force is the primary reference signal.
自由
CC0 1.0 (Zenodo record; other sources disagree)
2026-07-30
NONAN GaitPrint
NONAN GaitPrint: An IMU gait database of healthy young adults · 2023
The repeat structure is what makes it valuable: up to 18 four-minute walking trials per person across two days at 200 Hz, which is the only public source for within- and between-day wrist repeatability at this scale. Catches: gait events are algorithmic rather than human-annotated, there is no channel literally named wrist (forearm and hand bracket a watch position), signals carry a Noraxon 5 Hz anti-wobble filter, and the collection is 50 GB. CC0 applies to the DATA; the descriptor article is CC BY 4.0.
35
forearmhandheadtrunkpelvisthighshankfoot
200
ジャイロあり
歩行イベント
Per-sample stance/swing contact signals and per-step spatiotemporal parameters, both computed by Noraxon software from the FOOT IMUs — not an independent reference.
自由
CC0 1.0
2026-07-30
OxWalk
OxWalk: Wrist and hip-based activity tracker dataset for free-living step detection and gait recognition · 2022
Largest open free-living dataset with video-annotated per-step ground truth at the wrist, and the training set behind the OxWearables 'stepcount' model. Axivity AX3 loggers record acceleration only (no gyroscope), with a paired 100 Hz and 25 Hz device at each of the wrist and hip.
39
wristhip
100 / 25
加速度のみ
歩行イベント
Per-step heel-strike annotations transcribed from synchronised foot-facing action-camera video worn at the beltline.
自由
CC BY 4.0
2026-07-27
Step-Wise Annotated Multi-Gait IMU
Step-Wise Annotated Multi-Gait IMU Dataset from Smartphone, Smartwatch, and Earbuds · 2025
Rare per-step, per-foot manual labels time-synchronised with a wrist device (Apple Watch Series 10), which makes it directly usable for step-event work. Catch: only 11 of the 16 enrolled participants have signal data (P12 has labels but no data, P13–16 are empty), total recording is ~48 min, and all devices are delivered resampled onto one ~100 Hz timeline with earbud channels forward-filled; wrist side is unstated.
16 enrolled; 11 with data
wristpocketear
100 (phone, watch) / 25 (earbuds)
ジャイロあり
歩行イベント
Manual per-step annotations giving start/end sample indices with gait type and foot side (8 classes); the companion paper cites Xsens motion capture as reference but no mocap data is distributed.
自由
CC BY 4.0
2026-07-27
TOWalk
TOWalk: A Multi-Modal Dataset for Real-World Movement Analysis
Carries wrist gyroscope AND gait-event ground truth, which is the rarest combination in this index — but NC-ND blocks both commercial use and redistribution of derivatives. Listed so the trade-off is visible rather than rediscovered.
unknown
wristfootlower back
unknown
ジャイロあり
歩行イベント
INDIP wearable multi-sensor reference (foot-mounted magneto-inertial units plus additional sensors) giving gait events.
登録要
CC BY-NC-ND 4.0
2026-07-30
Multi-camera Posture and Gait
A multi-camera and multimodal dataset for posture and gait analysis (Smart Walker Database) · 2021
Open on PhysioNet with no credentialing, and the upper-limb units give six-axis data at 60 Hz against a full-body reference. Small cohort, and the walker context means the arms are not swinging freely — a real limitation for arm-swing-driven methods.
14
forearmheadshouldersternumupper armpelvisthighshankfoot
60
ジャイロあり
モーションキャプチャ
Xsens MTw Awinda inertial motion capture (MVN BIOMECH) providing full-body segment positions and orientations as the stated kinematic reference, alongside two depth cameras.
自由
CC BY 4.0
2026-07-30
TOLIFE Real-World Gait Speed
Real-World Gait Speed Estimation: Laboratory and Real-Life Patient Data from TOLIFE Wearables · 2025
Rare pairing of a consumer smartwatch (Galaxy Watch 5, 50 Hz accelerometer and gyroscope on the left or preferred wrist) with a full-body mocap gait-speed reference, plus a real-world COPD patient cohort; the paired smart shoes instrument both feet and the phone has no gyroscope. Catch: the linked Sensors 2024 descriptor documents only version 1 (20 healthy subjects) and the bundled Readme is the sole documentation for the newer subsets, and the free-living COPD recordings carry no per-window speed or activity labels.
88 across 4 subsets (25/15/10 healthy, 38 COPD)
wristpocketfoot
50 (wrist accel+gyro); phone 50, Xsens reference 60, smart shoes irregular
ジャイロあり
モーションキャプチャ
Xsens Awinda 17-IMU centre-of-mass horizontal velocity plus walked distances (gait-speed subset), annotated activity start/stop timestamps and known path lengths (activity-recognition and validation subsets), and the average of two clinician-administered 6MWT distances for the COPD cohort.
自由
CC BY 4.0
2026-07-27
Smartwatch Gait – Restricted Arm Swing
Smartwatch gait dataset in simulated Parkinson's disease restricted arm swing conditions · 2024
Rare wrist dataset in which arm-swing amplitude is the manipulated variable, openly downloadable with triaxial accelerometer (m/s^2) and gyroscope (rad/s) at 50 Hz. Catch: the '144 files' in the description are 144 trials stored as cells inside a single 3.9 MB .mat file, and there are no step-event annotations, no participant demographics and no named smartwatch model; the de facto data descriptor is Polvorinos-Fernández et al., BIOSTEC 2025, which the Zenodo record does not link.
24
wrist
50
ジャイロあり
行動ラベル
Per-trial condition labels only (load level 1–3) plus participant ID; no annotated step events and no external reference system.
自由
CC BY 4.0
2026-07-27
DUO-GAIT
DUO-GAIT: A gait dataset for walking under dual-task and fatigue conditions with inertial measurement units · 2023
Bilateral wrist IMUs with gyroscopes at 128 Hz suit arm-swing modelling, but the reference gait events are IMU-derived rather than from mocap, insoles or manual annotation. No license is declared on the Zenodo record (v1 was deposited as 'Other (Non-Commercial)', later blanked), so the frequently cited CC BY 4.0 covers only the article and reuse terms must be confirmed with the authors.
16
headchestlower backwristlegfoot
128
ジャイロあり
なし
No independent reference system - gait events and spatiotemporal parameters are computed from the foot IMUs with an error-state Kalman filter plus zero-velocity updates and shipped as 'processed' outputs.
自由
unknown
2026-07-27
Wrist–Tibia/Shoe IMU
Wrist and Tibia/Shoe Mounted IMU Measurement Results for Gait Analysis · 2023
Purpose-built for wrist-to-tibia/shoe signal translation (Kolakowski, Sensors 2024, doi:10.3390/s24010293), so the lower-limb IMU is the target signal and no step or gait-event labels ship with the data. Small and explicitly preliminary: 10 MB, 5 walks, 12 Python-only .pbz2 (pickle) files, wrist in all walks but all three sites simultaneously only in test1 and test5, and no participant count is stated anywhere; the widely quoted "85 min" is the authors' derived training-set size, not the recording duration.
unknown
wristtibiafoot
50
ジャイロあり
なし
None — the deposit contains no annotation or event files; the concurrently recorded tibia/shoe IMU signals serve as the translation target for the wrist signal, with no optical, pressure, video or manual reference.
自由
CC BY 4.0
2026-07-27

臨床コホート10

パーキンソン病・脳卒中・多発性硬化症など、疾患を持つ被験者の記録。多くはデータ利用同意書が必要です。

データセット被験者装着部位サンプリング正解ラベル入手確認日
WearGait-PD
WearGait-PD: An Open-Access Wearables Dataset for Gait in Parkinson's Disease and Age-Matched Controls · 2026
Largest clinical gait dataset carrying bilateral wrist IMUs (Xsens MTw Awinda, accel + gyro + magnetometer) alongside instrumented-walkway reference, so wrist signals can be regressed directly against stride parameters. Files live on Synapse and need free registration plus acceptance of the terms; the data descriptor (2026 publication year, data collected earlier) is open at PMC13009270.
185 (100 PD, 85 controls)
foreheadsternumlower backwristthighshankanklefootinsole
100
ジャイロあり
モーションキャプチャ
ProtoKinetics Zeno pressure-sensing walkway spatiotemporal gait parameters synchronised to all sensors, plus frame-by-frame dual-camera video annotation and clinical scores (MDS-UPDRS, Hoehn & Yahr, medication/DBS status).
登録要
CC BY 4.0
2026-07-27
BEAT-PD (CIS-PD + REAL-PD)
Biomarker and Endpoint Assessment to Track Parkinson's Disease (BEAT-PD) DREAM Challenge dataset - CIS-PD and REAL-PD cohorts · 2023
Wrist gyroscope exists only for the REAL-PD arm (Moto 360 Sport on the most-affected wrist); CIS-PD's Apple Watch Series 2 is accelerometer-only, and no cohort carries gait or step annotation, so this suits free-living/self-supervised work rather than step validation. Data arrive as 20-minute segments with ordering destroyed so continuous recordings cannot be reconstructed, and the commonly quoted counts (51 enrolled/39 completed CIS-PD, 25 PD + 25 controls REAL-PD) are parent-study enrollment - no controls are in the release.
43 released (CIS-PD 21, REAL-PD 22); 28 in main train/test
wristpocket (varies)
unknown
ジャイロあり
臨床情報
Self-reported diary labels at 30-minute intervals, released as medication on/off (0-4 in CIS-PD, binary in REAL-PD), dyskinesia and tremor severity; no gait, step-event, walking-bout or video annotation.
申請要
No open license; MJFF Data Use Agreement, no redistribution
2026-07-27
COPS
Continuous Observation of Parkinsonian Symptoms using Symptom Diaries & Wearable Accelerometry · 2026
Bilateral 100 Hz GENEActiv wrist accelerometry over ~394 participant-days, downloadable from OSF anonymously with no registration, but labels are self-reported at 1-hour granularity, so it supports motor-state and freezing-of-gait work and not stride- or step-event validation. 46 of the 66 participants have deep brain stimulation implanted, which materially affects gait and movement characteristics.
66
wrist
100
加速度のみ
臨床情報
Hourly patient-completed symptom diaries (kinetic ON/OFF 7-point, tremor, binary freezing of gait, falls, medication intake times) plus UPDRS-III in medication-ON and -OFF states; no gait, step or walking-bout annotation.
自由
CC BY 4.0
2026-07-27
FoG-STAR
FoG-STAR: Freezing of Gait Severity, Tasks, Activities, and Ratings · 2026
Wrist IMU with gyroscope at 60 Hz alongside FoG labels, but the reference is clinician-rated episodes and activity classes rather than per-step events, and the 30 fps annotation video is not distributed (only sensor and clinical CSVs are). Volume is small — mean 4.2 min per subject, ~1.5 h total — all recorded in the practically-defined OFF state after levodopa washout, and only one wrist is instrumented with the side varying by participant.
22
wristanklelower back
60
ジャイロあり
臨床情報
Video-derived annotation by two neurologists of 101 freezing-of-gait episode onsets/offsets with ordinal manifestation labels (shuffling, trembling, akinesia) and seven activity classes, plus subject-level clinical scores (Hoehn & Yahr, MDS-UPDRS III, FOG-Q, MoCA, FES-I, PDQ-8).
自由
CC BY 4.0
2026-07-27
FRAILPOL
Database for Prevalence and Determinants of Frailty in the Elderly with Quantifying Functional Mobility · 2026
The closest external cohort to this project's own input: both wrists at 100 Hz with gyroscope, and frailty labelled in three stages rather than a binary — which is the target where our own binary comparison cannot separate anything and the three-stage one can. 668 participants against our 213. The limit is the task: TUG is supervised and structured, so it can test whether three-stage frailty is readable from wrist six-axis data, not free-living performance. Five sensors (both wrists, both ankles, sacrum); 'lower back' here is the sacrum. Hosted on figshare (article 29315771 v3), not Zenodo as some secondary sources state; the licence was read from the figshare API record rather than the paper. 325 MB across seven files, of which the 292 MB IMU_signals.zip is the raw signal. Verified after download: IMU_signals.zip holds 3,341 CSVs, one per participant per site (left/right wrist, left/right ankle, sacrum), each 100 Hz with Acc XYZ in m/s2, Gyr XYZ in deg/s and roll/pitch/yaw. The 30-column parameter table is entirely left/right FOOT measures, so anything wrist-based has to be built from the raw wrist CSVs. Which of 0/1/2 is robust is not stated in the shipped description.
668
wristanklelower back
100
ジャイロあり
臨床情報
Three frailty classes assigned by established clinical criteria, with demographic, health and cognitive data attached; the shipped label column splits 342 / 279 / 47, so the frail group is 47 of 668 (7%). Spatiotemporal parameters ship alongside the raw signals but are derived from the ankle sensors by the same pipeline, so they are not an independent reference — and they are foot parameters, not wrist ones.
自由
CC BY 4.0
2026-09-02
MJFF Levodopa Response Study (limb and trunk)
Limb and trunk accelerometer data collected with wearable sensors from subjects with Parkinson's disease · 2021
Qualifies on forearm rather than wrist: the five Shimmer3 units sit on the forearms, shanks and L5, so signals differ from smartwatch data, and the wrist-worn GENEActiv/Pebble data of the same study is the separate 'minimum sensor set' record. There is no backwards-walking task (the dual-task is forward walking while counting backwards aloud), and the CC BY 4.0 belongs to the article, not the dataset, which is governed by Synapse Conditions of Use plus Certified User status.
17 (of 19 enrolled)
forearmshanklower back
50 (resampled from 51.2 native)
加速度のみ
臨床情報
Limb-specific scores from an MDS-UPDRS-certified clinician: tremor 0-4, dyskinesia 0-4, bradykinesia yes/no (0-4 only for rapid alternating hand movements), plus MDS-UPDRS Part III; no step events, video, motion capture or speed.
申請要
unknown
2026-07-27
MJFF Levodopa Response Study (minimum sensor set)
Accelerometer data collected with a minimum set of wearable sensors from subjects with Parkinson's disease (MJFF Levodopa Response Study) · 2021
Bilateral wrist accelerometry with clinician symptom ratings time-locked to several distinct labelled walking tasks, but accelerometer only, so no wrist angular velocity. The CC BY 4.0 usually quoted covers the article, not the data (Synapse syn20681023 needs a validated, certified account and an Intended Data Use statement); the Spaulding subgroup's five Shimmer3 units are released as the separate 'limb and trunk' record.
28 (of 31 enrolled)
wristwaist
50
加速度のみ
臨床情報
Clinician MDS-UPDRS Part III plus per-task tremor severity 0-4, dyskinesia and bradykinesia presence, with task start/end timestamps; no step events, motion capture or measured walking speed.
申請要
unknown
2026-07-27
PPMI (Verily Study Watch)
Parkinson's Progression Markers Initiative — Verily Study Watch digital sensor sub-study · 2018–2020 (wearable component)
Rare prodromal-PD cohort with continuous wrist accelerometer + gyroscope wear, but the 100 Hz rate comes only from a secondary analysis paper (Sensors 2022) — neither the PPMI access page nor the two wearable papers publishes a rate, and the earlier "30 Hz for non-PD cohorts" claim is unsupported. Access needs a signed PPMI Data Use Agreement via LONI IDA, Verily's derived-measure algorithms are proprietary, and it is undocumented whether raw gyroscope streams (as opposed to accelerometer) are actually distributed to applicants.
271 (111 PD, 138 prodromal, 22 controls)
wrist
100
—
臨床情報
In-person clinical assessment — MDS-UPDRS confirmed for this sub-study, other PPMI scales unverified — plus Verily-derived sleep, vital-sign and physical-activity summaries; no gait-event or stride-level labels.
申請要
DUA required
2026-07-27
Stroke Rehab IMU (Zenodo 10534055)
Dataset for Monitoring and Visualizing Stroke Rehabilitation Progress using Wearable Sensors (IMU) · 2024
Xsens wrist IMUs give acceleration, angular velocity, magnetometer and orientation quaternions at 120 Hz in a stroke cohort, but there is no optical mocap, video or walkway reference and no step/gait-event annotation. Wrist data is missing entirely from one of the 20 sessions (imu0011/visit1), and the short name "StrokeGait" is editorial — the record carries no short name and never states the sensor sites or rate (both read off the archive).
10 (2 visits each)
wristfootlower back
120
ジャイロあり
臨床情報
Clinical labels only — FAC scores at both visits, two clinician improvement ratings and demographics; the supplied stride parameters are the authors' own foot-IMU-derived outputs, not an independent reference.
自由
CC BY 4.0
2026-07-27
PerHeart Pilot
PerHeart Pilot Dataset: Wrist-worn Inertial Sensor and Physiological Data from Older Adults with Heart Failure · 2025
Rare six-axis wrist data from an older clinical population, which is the cohort most gait work actually targets. Only 8 of the 27 enrolled participants wore the wrist sensor, and there is no gait reference of any kind.
27 enrolled; 8 with wrist IMU
wrist
50
ジャイロあり
なし
None for gait — the record positions the data for semi-supervised learning rather than for validation.
自由
CC BY 4.0
2026-07-30

行動認識ベンチマーク17

行動認識のために作られ、歩行が行動クラスのひとつとして含まれるもの。歩行イベント単位の基準はありません。

データセット被験者装着部位サンプリング正解ラベル入手確認日
watchHAR
watchHAR: A Smartwatch IMU dataset for Activities of Daily Living · 2022
Both wrists are instrumented with six-axis data at 100 Hz and the reference is optical motion capture rather than another IMU — an unusually strong combination. Foot markers make it possible to derive contact events even though none are shipped.
21
wrist
100
ジャイロあり
モーションキャプチャ
Vicon optical motion capture at ~100 Hz, released as 3D marker positions for both hands and both feet.
自由
CC BY 4.0
2026-07-30
BandX-Activity
BandX-Activity: Human Activity Recognition Dataset with Demographics Using the MPU6050 Sensor · 2024
Six-axis wrist data with participant demographics attached, which is rarer than it should be. At 20 Hz the Nyquist limit is 10 Hz, too low for heel-strike timing; demographics cover only part of the 33 participants.
33
wrist
20
ジャイロあり
行動ラベル
Per-sample activity class labels only; no event, motion-capture or clinical reference.
自由
CC BY 4.0
2026-07-30
DSADS
Daily and Sports Activities · 2010
Unusually useful for gait because three walking conditions and one running condition carry known treadmill speeds while both arm units sit at the wrists (placement is documented in Altun/Barshan, Pattern Recognition 2010 — the UCI page says only "arms"). Catches: data ships only as pre-cut 5 s segments with no timestamps or step events, 25 Hz limits event timing to 40 ms, and the wrist units are the plus/minus 5 g pair so they can clip during running, jumping and basketball; donated to UCI in 2013.
8
wristchestknee
25
ジャイロあり
行動ラベル
Activity labels encoded by folder structure over pre-cut 5 s segments, with known treadmill reference speeds for the walking and running trials; no video or optical reference.
自由
CC BY 4.0
2026-07-27
ExtraSensory
The ExtraSensory Dataset: behavioral context recognition in-the-wild from mobile sensors · 2017; collected 2015-2016
Raw watch accelerometer ships as its own archive, so wrist-only use does not require the multi-gigabyte phone streams — but the watch has no gyroscope, labels are self-report, and the cohort is university-age. HTTP-only host: an index or fetcher that upgrades to HTTPS records it as dead. No licence instrument is stated, only a citation condition.
60 (56 with wrist data)
wristphone
25 (wrist)
加速度のみ
行動ラベル
Self-reported labels entered in the study app; no camera, diary or observer reference.
自由
unknown
2026-07-30
GeoTecINIT phone+watch HAR
Smartphone and smartwatch inertial measurements from heterogeneous subjects for human activity recognition · 2023
Six-axis wrist data at ~100 Hz with an age range of 23-66, wider than the usual student cohort. The walking is a short Timed-Up-and-Go leg, on the order of twenty minutes of wrist walking across the whole cohort, so it suits transition detection rather than sustained gait. The GitHub licence badge says Apache-2.0, which governs the code, not the data.
23
wristphone
100
ジャイロあり
行動ラベル
Per-sample activity labels produced by frame-level manual inspection of 60 fps video to locate transitions; no step-level annotation.
自由
CC BY 4.0
2026-07-30
HHAR
Heterogeneity Human Activity Recognition Dataset (from Smartphones and Smartwatches) · 2015
Sampling-rate and device heterogeneity is the whole point — actual per-device rates deviate from nominal and drift, so it is a rate-robustness stress test rather than a clean gait source and you must not assume a uniform rate for cadence. Gyroscope exists only in the activity-recognition subset (the still-experiment files are accelerometer-only), and the four smartwatches are worn two per arm, so placement is arm/forearm with exact wrist position undocumented.
9
wristforearmwaist
100-200 (watch) / 50-200 (phone), unstable
ジャイロあり
行動ラベル
Per-sample scripted activity labels with a seventh "null" class for unlabelled and transition periods; no step events, treadmill speed, video or motion capture (an Xsens reference was used only in a static zero-g offset test).
自由
CC BY 4.0 (UCI page)
2026-07-27
ITB-HAR
ITB-HAR: Dataset for Human Activity Recognition Using Multisensor Wearable Device and Deep Learning · 2026
Nine-axis at the wrist including a magnetometer, but weak for gait on every other axis: 25 Hz, signals already low-pass filtered and smoothed with no raw release, transitions deliberately deleted, and roughly 6.6 hours total across 16 subjects and 12 activities. Requires a paid IEEE DataPort subscription despite the CC BY licence.
16
wrist
25
ジャイロあり
行動ラベル
Activity class labels only; no per-step or gait-event annotation.
登録要
CC BY (version ambiguous across IEEE's own pages)
2026-07-30
Labeled Raw Accelerometry (walk / stairs / drive)
Labeled raw accelerometry data captured during walking, stair climbing and driving · 2021
Left-wrist accelerometer recorded simultaneously with left hip and both ankles under a controlled outdoor walking protocol on four ActiGraph GT3X+ units (accelerometer only — not the gyroscope-carrying GT9X Link). Only activity-type labels ship with the data: any ankle-derived step reference must be computed by the user and is not part of the record, and the ODbL share-alike terms differ from CC BY.
32
wristhipankle
100
加速度のみ
行動ラベル
Activity-type label at every time point of data collection (1 = walking, 2 = descending stairs, 3 = ascending stairs, 4 = driving, 77 = clapping, 99 = non-study activity), with no per-step or per-stride event annotation distributed.
自由
ODbL v1.0
2026-07-27
MHEALTH
MHEALTH (Mobile HEALTH) Dataset · 2014
Right-wrist Shimmer2 unit carrying accelerometer, gyroscope and magnetometer at 50 Hz, with the side fixed for all subjects (unlike PAMAP2's dominant-arm rule), collected out-of-lab with no constraints on execution style. The wrist unit is documented as "right-lower-arm" in the column list, the chest unit contributes acceleration and 2-lead ECG only (no gyroscope or magnetometer columns), and roughly 1 min per activity across 10 subjects means very little walking data.
10
wristchestankle
50
ジャイロあり
行動ラベル
Per-sample activity label (column 24; labels 1-12 with 0 as the null class); the UCI page states each session was recorded with a video camera, but whether that video is distributed is unknown.
自由
CC BY 4.0
2026-07-27
OPPORTUNITY
OPPORTUNITY Activity Recognition Dataset · 2012
The gyroscope lives on the lower-arm IMUs (RLA/LLA), not on the wrist units — RWR/LWR are 3-axis accelerometer only, so a wrist-only consumer gets no rate-of-turn. Walking is an explicit label but a minority of each recording (~13% of S1-ADL1) with only 4 subjects, and the docs warn of ~100 ms inter-system and label jitter that matters for step-event timing.
4 (6 runs each)
wristforearmupper armbackhipkneeshoe
30
ジャイロあり
行動ラベル
Multi-track manual annotation (4 locomotion modes incl. Walk, 5 high-level activities, 17 mid-level gestures, per-arm action/object primitives), labelled during recording and reviewed by two annotators against video that is not distributed.
自由
CC BY 4.0 (UCI-applied)
2026-07-27
PAAWS
Physical Activity Assessment Using Wearable Sensors (PAAWS) Dataset · 2025-2026 (staged release)
Unusually large for a labelled wearable study and the annotation is second-by-second rather than bout level, but the gyroscope exists only in the lab protocol; the free-living arm is accelerometer-only. No licence is stated anywhere on the study site, so reuse terms are unconfirmed.
252 (lab); 237 free-living
wristwaistthighankle
80 accel / 100 gyro
ジャイロあり
行動ラベル
Second-by-second expert manual annotation from video — a third-person camera in the lab and a chest-mounted camera during waking hours.
自由
unknown
2026-07-30
PAMAP2
PAMAP2 Physical Activity Monitoring · 2012
The most-used multi-position HAR benchmark that genuinely includes a wrist IMU (3D accelerometer, gyroscope and magnetometer at 100 Hz) with walking, Nordic walking, running and stairs in the activity set. Wrist is on the dominant arm so side varies across subjects, the wrist block is named "IMU hand" (columns 4-20) in the file schema, the per-IMU orientation columns are flagged invalid by the authors, and missing values are NaN.
9
wristchestankle
100 (IMUs) / ~9 (heart rate)
ジャイロあり
行動ラベル
Per-sample activity label (column 2 of each .dat file), described by the repository as the ground truth and following the scripted collection protocol; no video or optical reference appears in the release.
自由
CC BY 4.0
2026-07-27
REALDISP
REALDISP (REAListic sensor DISPlacement) Activity Recognition Dataset · 2012
Best public set for testing how robust a wrist/forearm gait algorithm is to strap rotation and translation, thanks to its three placement scenarios (ideal, self-placed, deliberately displaced; the displaced scenario covers only subjects 2, 5, 15). Catches: the arm units are mid-forearm, not wrist, labels are activity-level only, and recordings are missing for subjects 6 and 13 (self-placement) and nearly all of subject 7 (ideal); rate and placement come from Banos et al., Sensors 2014, not the UCI page.
17
forearmupper armbackthighcalf
50
ジャイロあり
行動ラベル
Activity-level labels annotated online by the experimenter with the CRN Toolbox and later reviewed against video recordings that are not released; no motion capture, treadmill speed or step-event reference.
自由
CC BY 4.0
2026-07-27
RealWorld-2016
RealWorld (HAR) 2016 Dataset · 2016
The same 8 activities are recorded simultaneously at 7 body positions on the same 15 subjects, so forearm signals can be regressed directly against thigh/shin/waist. The landing page states no rate or licence: 50 Hz comes from the readMe bundled in each archive, and the demonstration videos live only on the per-subject pages, not in the ~3.5 GB bulk download.
15
chestforearmheadshinthighupperarmwaist
50 (~49.7-50.0 measured)
ジャイロあり
行動ラベル
Activity labels from the scripted recording protocol, plus one demonstration video per activity per subject; no step-event, motion-capture or speed reference.
自由
unknown
2026-07-27
Smartwatch Gait – Stairs
Smartwatch gait dataset in normal, upstairs and downstairs conditions · 2025
Wrist smartwatch accelerometer + gyroscope at 50 Hz (m/s^2 and rad/s), but the only labels are gait condition and participant ID, so it suits condition classification rather than step detection. The 72 trials ship as one .mat file (not 72 files, as often reported), and although Zenodo tags the record "Parkinson's Disease" the cohort is entirely healthy.
24
wrist
50
ジャイロあり
行動ラベル
Per-sample gait-condition label (1=normal, 2=upstairs, 3=downstairs) and participant ID; no step events, mocap, video or clinical scores.
自由
CC BY 4.0
2026-07-27
SPHERE house scripted
SPHERE house scripted dataset: a multi-sensor dataset with annotated activities of daily living recorded in a residential setting · 2022 (v2.0); recorded 2016
Catalogued as smart-home research, which is why gait searches miss it. The 20 Hz wrist stream suits ambulation classification rather than step timing, and it arrives over connectionless BLE with no delivery guarantee, so the grid is gappy. The 872 test folders are shuffled slices, not participants.
10
wrist
20
加速度のみ
行動ラベル
Trained annotators labelled posture, ambulation, activity and location in ELAN against head-mounted 4K reference video; every sequence was annotated by two or three people and interrater kappa is published.
自由
CC BY 4.0
2026-07-30
WISDM-2019
WISDM Smartphone and Smartwatch Activity and Biometrics Dataset · 2019
Largest subject count of the classic UCI wrist HAR sets (51) and its deliberate contrast between ambulation and hand-dominated activities is exactly the confounder set a wrist step counter must reject. Two traps: the 20 Hz rate is a nominal OS polling request, not guaranteed, and the raw timestamps are Android nanosecond uptime counters despite the README calling them Unix time — do not treat them as epoch when deriving cadence.
51
wristpocket
20
ジャイロあり
行動ラベル
Per-sample activity codes from a scripted 3-minute-per-activity protocol, plus pre-computed 10 s window features; no video or optical reference, but subject IDs are retained for biometrics.
自由
CC BY 4.0
2026-07-27

大規模コホート5

疫学研究の加速度計コホート。規模は桁違いですが歩行ラベルは無いので、アルゴリズムの検証には使えません。事前学習の材料、または転帰との紐付けに使うものです。

データセット被験者装着部位サンプリング正解ラベル入手確認日
CAPTURE-24
CAPTURE-24: A large dataset of wrist-worn activity tracker data collected in the wild for human activity recognition · 2021 (deposit); collected 2014-2016; descriptor 2024
The reference labelled wrist dataset and the training set behind most UK Biobank activity models, with walking as an explicit label — but accelerometer-only, and labels are activity-bout level, so there are no step events, heel strikes or walking speed. The data is CC BY 4.0 while the OxWearables benchmark CODE carries a non-commercial Oxford licence; the two are routinely conflated.
151
wrist
100
加速度のみ
行動ラベル
Wearable-camera annotation: a neck-worn Autographer photographed every 20-40 s and trained annotators coded the images to activity codes; sleep came from a two-question diary.
自由
CC BY 4.0
2026-07-30
GOTOV
GOTOV Human Physical Activity and Energy Expenditure Dataset on Older Individuals · 2021 (v2); collection period unknown
One of very few labelled wrist datasets in adults over 60, with a simultaneous energy-expenditure criterion — but NC-SA blocks commercial use, there is no gyroscope, and the 300 s walking bouts exist for only 25 of the 35 participants. The published collection dates contradict the shipped per-session timestamps, so the year is left unconfirmed.
35
wristanklechest
83
加速度のみ
行動ラベル
Researcher-observed activity start and end times imputed onto samples; energy expenditure from simultaneous indirect calorimetry (COSMED).
自由
CC BY-NC-SA 4.0
2026-07-30
IMU50
IMU50: a high-frequency multi-modal wrist-worn IMU dataset of 50 subjects over 5 continuous days · 2026
The largest free-living wrist dataset with a GYROSCOPE at a usable rate, which almost nothing else offers — research-grade wrist loggers are overwhelmingly accelerometer-only. Nothing marks where walking occurs, so it suits pre-training rather than validation. Single 46.7 GB download.
50
wrist
128
ジャイロあり
なし
None — the record states no activity labels were collected, the resource being intended for unsupervised and self-supervised learning.
自由
CC BY 4.0
2026-07-30
NHANES PAM (2011–2014)
National Health and Nutrition Examination Survey, Physical Activity Monitor — Raw Data 80 Hz (PAX80_G, 2011–2012; PAX80_H, 2013–2014) · Collected 2011–2014; raw 80 Hz files published 2022
Largest fully open raw wrist-accelerometry population dataset — per-participant tar.bz2 archives on the CDC FTP with no registration, ~1.04 TB compressed for the 2011–2012 half alone; the 2013–2014 half is the separate PAX80_H record, and 247 children aged 3–5 are withheld to the NCHS Research Data Center. Walking is present but nothing marks where it occurs, so it is unusable as a step-detection or gait-parameter validation set; the ActiGraph GT3X+ records triaxial acceleration plus 1 Hz ambient light and no gyroscope, and NCHS use restrictions (statistical use, no re-identification or linkage) still apply.
14,693 (plus 1,477 NNYFS)
wrist
80
加速度のみ
なし
None — documentation states no activity logs, diaries or records were kept; only per-participant QC flag files marking implausible signal segments (~0.26%) accompany the data.
自由
unknown (NCHS Data User Agreement applies)
2026-07-27
UK Biobank Accelerometer Study
UK Biobank Physical Activity Monitoring (accelerometer) sub-study — Data-Field 90001, 'Acceleration data - cwa format' · 2013–2016 (dates differ across UKB sources); seasonal repeats Nov 2017–Jan 2019
The reference population-scale wrist dataset and raw data really is released (Axivity AX3 .cwa, ~250 MB per 7-day wear, nominal 100 Hz but true rate fluctuates 94–104 Hz at ±8 g), yet it is accelerometer-only with zero step or gait-event labels — the widely used UKB step models are trained on CAPTURE-24/OxWalk and merely deployed here. Access is by application under the Material Transfer Agreement with bulk-retrieval charges, and was reported suspended as of July 2026 after the Research Analysis Platform closure — verify current status before planning work.
103,568 (112,330 bulk items; per-instance split unknown)
wrist
100
加速度のみ
なし
None — no diary, camera or observer annotation accompanies the recordings; the Showcase activity-class fields are algorithm outputs rather than labels.
申請要
UK Biobank MTA (no open licence)
2026-07-27

収録の基準と、この索引の限界

収録するのは「手首または前腕に慣性センサーがあり」「歩行が記録されている」データセットに限ります。腰・大腿・足部のみのものは、歩行研究でどれだけ有名でも対象外です。

各項目は必ずデータセット自身の配布ページかデータ論文で確認し、確認できなかった項目は推測せず unknown と表示します。確認した日付を各行に出しているので、古い行は古いと分かります。

サーベイ論文は出版時点で凍結しますが、この索引は壊れたリンクや新しい寄託を反映し続けることを前提に置いています。抜けや誤りを見つけたら指摘してください。

確認したが収録しなかったもの

手首と歩行の条件は満たすものの、生の慣性波形が入手できると確認できなかったため収録していません。派生サマリー(1日あたりの活動量など)しか出ないなら、信号の索引に載せる意味がないためです。同じ調査を繰り返さずに済むよう、理由とともに残しておきます。

データセット規模収録しなかった理由
China Kadoorie Biobank accelerometer sub-study22,511Unconfirmed whether applicants receive raw 100 Hz .cwa signals or only derived daily summaries.
Fenland Study1,695The data-sharing page lists only processed accelerometer variables; raw 60 Hz access is unconfirmed even on application.
Pelotas birth cohorts wrist accelerometry8,974No dataset record exists; access is informal collaboration and it is unknown whether the raw files have ever been released.
Rotterdam Study - GENEActiv wrist accelerometer sub-study1,410No repository record or dataset DOI; release of raw 50 Hz signals rather than derived summaries is unconfirmed.
Whitehall II accelerometer sub-study3,953Unconfirmed whether raw 85.7 Hz signals are released at all rather than derived summaries. Worth revisiting: it is the only cohort pairing free-living wrist data with a clinic-measured walking speed per participant, at ages 60-83.

抜けているデータセットを知っていますか

この索引は網羅を主張しません。条件を満たすのに載っていないものや、内容が古くなっている行があれば教えてください。データ自体を提供いただける場合も歓迎します。